Oil cooler with oil tank 5000W~20000W
- CNC Lathe
- NC Special Purpose Machine
- CNC Punch Press
- CNC Machining Center
- CNC Grinding Machine
- CNC E.D.M
- Various Hydraulic Equipment
- Spindle Oil Cooling
- Oil Cooling
- Gear Lubricating Oil Cooling
- Hydraulic Oil Cooling
- Lubricating Oil Cooling
- Grinding Oil Cooling
- Cutting Oil Cooling
- Above cooling capacity is tested under the conditions of ambient temperature 35°c, oil outlet temperature 35°c, and oil grade ISO VG32.
- Contact us when special specifications are required.
- Design and specifications are subjec to change without prior notice.
- Oil tank is an optional equipment. Speicity your requirement when ordering.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 3600 ( 50 Hz) 4500 ( 60 Hz) |
| W | 4185 / 5230 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 16 ( 50 Hz) 20 ( 60 Hz) |
In / Out Port Size | Inch | PT 1" |
Dimension | With tank | 510-710-1300 |
Capacity Of Liquid Tank | Liter | 45 |
Weight KG | With tank | 170 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 4800 ( 50 Hz) 6000 ( 60 Hz) |
| W | 5580/ 6975 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 24 ( 50 Hz) 30 ( 60 Hz) |
In / Out Port Size | Inch | PT 1" |
Dimension | With tank | 510-710-1300 |
Capacity Of Liquid Tank | Liter | 45 |
Weight KG | With tank | 170 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 7200 ( 50 Hz) 9000 ( 60 Hz) |
| W | 8370 / 10465 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 32 ( 50 Hz) 40 ( 60 Hz) |
In / Out Port Size | Inch | PT 1" |
Dimension | With tank | 660-835-1400 |
Capacity Of Liquid Tank | Liter | 60 |
Weight KG | With tank | 220 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 9600 ( 50 Hz) 12000 ( 60 Hz) |
| W | 11160 / 13950 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 50 ( 50 Hz) 70 ( 60 Hz) |
In / Out Port Size | Inch | PT 1-1/4" |
Dimension | With tank | 1110-710-1560 |
Capacity Of Liquid Tank | Liter | - |
Weight KG | With tank | 265 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 12000 ( 50 Hz) 15000 ( 60 Hz) |
| W | 13920 / 17400 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 50 ( 50 Hz) 70 ( 60 Hz) |
In / Out Port Size | Inch | PT 1-1/4" |
Dimension | With tank | 1110-710-1560 |
Capacity Of Liquid Tank | Liter | - |
Weight KG | With tank | 280 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 14400 ( 50 Hz) 18000 ( 60 Hz) |
| W | 16704 / 20880 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 60 ( 50 Hz) 75 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
Dimension | With tank | 1130-750-1830 |
Capacity Of Liquid Tank | Liter | 100 |
Weight KG | With tank | 300 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.