Oil cooler with oil tank Below 5000W
- CNC Lathe
- NC Special Purpose Machine
- CNC Punch Press
- CNC Machining Center
- CNC Grinding Machine
- CNC E.D.M
- Various Hydraulic Equipment
- Spindle Oil Cooling
- Oil Cooling
- Gear Lubricating Oil Cooling
- Hydraulic Oil Cooling
- Lubricating Oil Cooling
- Grinding Oil Cooling
- Cutting Oil Cooling
- Above cooling capacity is tested under the conditions of ambient temperature 35°c, oil outlet temperature 35°c, and oil grade ISO VG32.
- Contact us when special specifications are required.
- Design and specifications are subjec to change without prior notice.
- Oil tank is an optional equipment. Speicity your requirement when ordering.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 800 ( 50 Hz) 1000 ( 60 Hz) |
| W | 925 / 1160 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 4.5 ( 50 Hz) 7.2 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
Dimension | With tank | 380-480-690 |
Capacity Of Liquid Tank | Liter | 6 |
Weight KG | With tank | 55 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 800 ( 50 Hz) 1000 ( 60 Hz) |
| W | 925 / 1160 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 4.5 ( 50 Hz) 7.2 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
Dimension | With tank | 370-440-832 |
Capacity Of Liquid Tank | Liter | 10 |
Weight KG | With tank | 60 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 800 ( 50 Hz) 1000 ( 60 Hz) |
| W | 925 / 1160 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 4.5 ( 50 Hz) 7.2 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
Dimension | With tank | 475-450-950 |
Capacity Of Liquid Tank | Liter | 15 |
Weight KG | With tank | 70 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 1200 ( 50 Hz) 1500 ( 60 Hz) |
| W | 1390 / 1740 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 12 ( 50 Hz) 15 ( 60 Hz) |
In / Out Port Size | Inch | PT 3/4" |
Dimension | With tank | 552-570-1185 |
Capacity Of Liquid Tank | Liter | 25 |
Weight KG | With tank | 112 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 1600 ( 50 Hz) 2000 ( 60 Hz) |
| W | 1860 / 2325 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 12 ( 50 Hz) 15 ( 60 Hz) |
In / Out Port Size | Inch | PT 3/4" |
Dimension | With tank | 552-570-1185 |
Capacity Of Liquid Tank | Liter | 25 |
Weight KG | With tank | 112 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 2400 ( 50 Hz) 3000 ( 60 Hz) |
| W | 2790 / 3488 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 16 ( 50 Hz) 20 ( 60 Hz) |
In / Out Port Size | Inch | PT 3/4" |
Dimension | With tank | 552-570-1185 |
Capacity Of Liquid Tank | Liter | 25 |
Weight KG | With tank | 112 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.