Oil cooler with oil tank Above 20000W
- CNC Lathe
- NC Special Purpose Machine
- CNC Punch Press
- CNC Machining Center
- CNC Grinding Machine
- CNC E.D.M
- Various Hydraulic Equipment
- Spindle Oil Cooling
- Oil Cooling
- Gear Lubricating Oil Cooling
- Hydraulic Oil Cooling
- Lubricating Oil Cooling
- Grinding Oil Cooling
- Cutting Oil Cooling
- Above cooling capacity is tested under the conditions of ambient temperature 35°c, oil outlet temperature 35°c, and oil grade ISO VG32.
- Contact us when special specifications are required.
- Design and specifications are subjec to change without prior notice.
- Oil tank is an optional equipment. Speicity your requirement when ordering.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 18000 ( 50 Hz) 22500 ( 60 Hz) |
| W | 20880 / 26100 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 120 ( 50 Hz) 150 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
Dimension | With tank | 1350-850-1850 |
Capacity Of Liquid Tank | Liter | 150 |
Weight KG | With tank | 400 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 24000 ( 50 Hz) 30000 ( 60 Hz) |
| W | 27840 / 34800 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 150 ( 50 Hz) 180 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
Dimension | With tank | 1350-850-1850 |
Capacity Of Liquid Tank | Liter | 200 |
Weight KG | With tank | 450 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 36000 ( 50 Hz) 45000 ( 60 Hz) |
| W | 41760 / 52200 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 200 ( 50 Hz) 250 ( 60 Hz) |
In / Out Port Size | Inch | PT 2 1/2" |
Dimension | With tank | 1650-1235-1850 |
Capacity Of Liquid Tank | Liter | 300 |
Weight KG | With tank | 500 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Hydraulic Oil, Lubricating Oil 4 - 300 cSt | |
| Cooling Capacity | kcal/hr | 48000 ( 50 Hz) 60000 ( 60 Hz) |
| W | 55680 / 69600 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 15 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 200 ( 50 Hz) 300 ( 60 Hz) |
In / Out Port Size | Inch | PT 2 1/2" |
Dimension | With tank | 2200-800-2050 |
Capacity Of Liquid Tank | Liter | 350 |
Weight KG | With tank | 600 |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.