Water Cooler Unit without water tank Above 20000W
- CNC Lathe
- CNC Machining Center
- CNC Wire Cutting Machine
- PCB Drilling or Routing Machine
- Medical Appliances
- Injection Machine
- Laser Cutting & Marking Machine
- Chiller of Low Temperature (-35°C)
- Food Machine
- All Product Equipments & Instruments for Semiconductor.
- High Speed Spindle
- Laser
- Cooling Water for Cutting Machine
- Mold Cooling
- Vacuum Pump
- All Equipments Needed to Cool by Water
- Above cooling capacity is tested under the conditions of ambinet temperature 32°C, liquid temperature 22°C and AC 220V 60 Hz.
- The ma ximum pressure resistance of evaporator is 5 kg /cm 2 , When a higher pressure pump is required, contact us.
- When further details of specifications are required, contact us.
- Design and specifications are subject to change without prior notice.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 14400 ( 50 Hz) 18000 ( 60 Hz) |
| W | 16745 / 20930 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 64 ( 50 Hz) 80 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
| Dimension WхDхH mm | W-D-H mm | 1120-710-1785 |
| Liter | 120 | |
| Weight KG | No tank | 250 |
| With tank | 300 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 18000 ( 50 Hz) 22500 ( 60 Hz) |
| W | 20925 / 26160 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 106 ( 50 Hz) 133 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
| Dimension WхDхH mm | W-D-H mm | 1300-800-1820 |
| Liter | 160 | |
| Weight KG | No tank | 350 |
| With tank | 400 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 24000 ( 50 Hz) 30000 ( 60 Hz) |
| W | 27905 / 34880 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 106 ( 50 Hz) 133 ( 60 Hz) |
In / Out Port Size | Inch | PT 2" |
| Dimension WхDхH mm | W-D-H mm | 1300-800-1820 |
| Liter | 190 | |
| Weight KG | No tank | 400 |
| With tank | 450 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 36000 ( 50 Hz) 45000 ( 60 Hz) |
| W | 41860 / 52325 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 160 ( 50 Hz) 200 ( 60 Hz) |
In / Out Port Size | Inch | PT 2 1/2" |
| Dimension WхDхH mm | W-D-H mm | 2220-850-2070 |
| Liter | 250 | |
| Weight KG | No tank | 450 |
| With tank | 500 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 48000 ( 50 Hz) 60000 ( 60 Hz) |
| W | 55810 / 69765 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 160 ( 50 Hz) 200 ( 60 Hz) |
In / Out Port Size | Inch | PT 2 1/2" |
| Dimension WхDхH mm | W-D-H mm | 2220-850-2070 |
| Liter | 300 | |
| Weight KG | No tank | 520 |
| With tank | 600 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.