Water Cooler Unit without water tank Below 5000W
- CNC Lathe
- CNC Machining Center
- CNC Wire Cutting Machine
- PCB Drilling or Routing Machine
- Medical Appliances
- Injection Machine
- Laser Cutting & Marking Machine
- Chiller of Low Temperature (-35°C)
- Food Machine
- All Product Equipments & Instruments for Semiconductor.
- High Speed Spindle
- Laser
- Cooling Water for Cutting Machine
- Mold Cooling
- Vacuum Pump
- All Equipments Needed to Cool by Water
- Above cooling capacity is tested under the conditions of ambinet temperature 32°C, liquid temperature 22°C and AC 220V 60 Hz.
- The ma ximum pressure resistance of evaporator is 5 kg /cm 2 , When a higher pressure pump is required, contact us.
- When further details of specifications are required, contact us.
- Design and specifications are subject to change without prior notice.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 800 ( 50 Hz) 1000 ( 60 Hz) |
| W | 925 / 1160 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 7.2 ( 50 Hz) 14 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
| Dimension WхDхH mm | W-D-H mm | 565-325-665 |
| Liter | 6 | |
| Weight KG | No tank | 38 |
| With tank | 45 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 1200 ( 50 Hz) 1500 ( 60 Hz) |
| W | 1390 / 1740 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 26 ( 50 Hz) 33 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
| Dimension WхDхH mm | W-D-H mm | 515-600-1150 |
| Liter | 20 | |
| Weight KG | No tank | 85 |
| With tank | 100 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 1600 ( 50 Hz) 2000 ( 60 Hz) |
| W | 1860 / 2325 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 26 ( 50 Hz) 33 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
| Dimension WхDхH mm | W-D-H mm | 515-600-1150 |
| Liter | 20 | |
| Weight KG | No tank | 85 |
| With tank | 100 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.
| Power Source | Main Power Source Voltage | 3 ~ 220 VAC 50 /60 Hz |
| Control Circuit Voltage | 24 VDC / 220VAC | |
| Applicadle Fluid | Water (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9) | |
| Cooling Capacity | kcal/hr | 2400 ( 50 Hz) 3000 ( 60 Hz) |
| W | 2790 / 3488 | |
| Temperature Control | Fixed Temperature | Fixed Temperature(Setting Range: 10 - 40°C) |
| Differential Temperature | Differential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C) | |
| Adjusing according machine temperation | Differential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C) | |
Ambient Temperature Working Rang | Envirtonmental Temperature | 5~ 40 ℃ |
| Fluid Temperature | 10~ 40 ℃ | |
Pump Flow | L / min | 26 ( 50 Hz) 33 ( 60 Hz) |
In / Out Port Size | Inch | PT 1/2" |
| Dimension WхDхH mm | W-D-H mm | 515-600-1150 |
| Liter | 20 | |
| Weight KG | No tank | 90 |
| With tank | 100 | |
1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.