Water Cooler Unit with water tank Below 5000W

Applicable Machines
  • CNC Lathe
  • CNC Machining Center
  • CNC Wire Cutting Machine
  • PCB Drilling or Routing Machine
  • Medical Appliances
  • Injection Machine
  • Laser Cutting & Marking Machine
  • Chiller of Low Temperature (-35°C)
  • Food Machine
  • All Product Equipments & Instruments for Semiconductor.
Application
  • High Speed Spindle
  • Laser
  • Cooling Water for Cutting Machine
  • Mold Cooling
  • Vacuum Pump
  • All Equipments Needed to Cool by Water
Notices
  • Above cooling capacity is tested under the conditions of ambinet temperature 32°C, liquid temperature 22°C and AC 220V 60 Hz.
  • The ma ximum pressure resistance of evaporator is 5 kg /cm 2 , When a higher pressure pump is required, contact us.
  •  
    When further details of specifications are required, contact us.
  • Design and specifications are subject to change without prior notice.

Power SourceMain Power Source Voltage 3 ~ 220 VAC 50 /60 Hz
Control Circuit Voltage24 VDC / 220VAC
Applicadle FluidWater (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9)
Cooling Capacity kcal/hr

  800  ( 50 Hz)

1000  ( 60 Hz)

W925 / 1160
Temperature ControlFixed TemperatureFixed Temperature(Setting Range: 10 - 40°C)
Differential TemperatureDifferential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C)
Adjusing according machine temperationDifferential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C)

Ambient Temperature Working Rang

Envirtonmental Temperature 

5~ 40 ℃
Fluid Temperature10~ 40 ℃

Pump Flow

L / min

7.2  ( 50 Hz)

14   ( 60 Hz)

In / Out Port Size

Inch

PT  1/2"
Dimension
WхDхH mm
W-D-H mm565-325-665
Liter6
Weight KGNo tank38
With tank45

 

1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.

 


Power SourceMain Power Source Voltage 3 ~ 220 VAC 50 /60 Hz
Control Circuit Voltage24 VDC / 220VAC
Applicadle FluidWater (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9)
Cooling Capacity kcal/hr

1200  ( 50 Hz)

1500  ( 60 Hz)

W1390 / 1740
Temperature ControlFixed TemperatureFixed Temperature(Setting Range: 10 - 40°C)
Differential TemperatureDifferential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C)
Adjusing according machine temperationDifferential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C)

Ambient Temperature Working Rang

Envirtonmental Temperature 

5~ 40 ℃
Fluid Temperature10~ 40 ℃

Pump Flow

L / min

26  ( 50 Hz)

33   ( 60 Hz)

In / Out Port Size

Inch

PT  1/2"
Dimension
WхDхH mm
W-D-H mm515-600-1150
Liter20
Weight KGNo tank85
With tank100

 

1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.

 


Power SourceMain Power Source Voltage 3 ~ 220 VAC 50 /60 Hz
Control Circuit Voltage24 VDC / 220VAC
Applicadle FluidWater (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9)
Cooling Capacity kcal/hr

1600  ( 50 Hz)

2000  ( 60 Hz)

W1860 / 2325
Temperature ControlFixed TemperatureFixed Temperature(Setting Range: 10 - 40°C)
Differential TemperatureDifferential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C)
Adjusing according machine temperationDifferential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C)

Ambient Temperature Working Rang

Envirtonmental Temperature 

5~ 40 ℃
Fluid Temperature10~ 40 ℃

Pump Flow

L / min

26  ( 50 Hz)

33   ( 60 Hz)

In / Out Port Size

Inch

PT  1/2"
Dimension
WхDхH mm
W-D-H mm515-600-1150
Liter20
Weight KGNo tank85
With tank100

 

1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.

 


Power SourceMain Power Source Voltage 3 ~ 220 VAC 50 /60 Hz
Control Circuit Voltage24 VDC / 220VAC
Applicadle FluidWater (To add any other liquid for antifrezzen, antirust that must benon-sulfur and PH shall be between 5 ~ 9)
Cooling Capacity kcal/hr

2400  ( 50 Hz)

3000  ( 60 Hz)

W2790 / 3488
Temperature ControlFixed TemperatureFixed Temperature(Setting Range: 10 - 40°C)
Differential TemperatureDifferential Temperature(Room Temperature/Fluid Temperature, Setting Range: -15 ~ + 15°C)
Adjusing according machine temperationDifferential Temperature. Liquild temperature Synchronized Adjustment with spindle column.(Fluid Temperature / Casting Temperature, Setting Range: -15 ~ + 15°C)

Ambient Temperature Working Rang

Envirtonmental Temperature 

5~ 40 ℃
Fluid Temperature10~ 40 ℃

Pump Flow

L / min

26  ( 50 Hz)

33   ( 60 Hz)

In / Out Port Size

Inch

PT  1/2"
Dimension
WхDхH mm
W-D-H mm515-600-1150
Liter20
Weight KGNo tank90
With tank100

 

1. All cooling capacity at an ambient temperature of 32 ℃, outlet liquid temperature of 25 ℃ and 220VAC 60Hz are measured.
2. Special voltage and specifications requested, please contact us.
3. Due to technological upgrading and quality improvement and change this specification without notice.
4. kcal/hr*3.968=BTU
5.The filter cans and filter elements are optional products, some models are recommended to be installed. If need our suggestions, please contact the business department.

 

0
SERVICE
CONTACT
NEWS
TOP